我們把質量優先的文化貫徹到整個組織與業務過程;以零缺陷為目標,構建全鏈條的質量管理體系我們致力于通過持續改善,為客戶提供一流的產品與服務,讓客戶滿意。
We build Quality First culture inthe entire organization and businessprocesses, We develop the qualitymanagement system with zero defecttarget.We strive to provide the world classproduct and service quality to ourcustomers through continuousimprovement process
| Item | Test conditions | Duration | Sample size | Acceptance/Reject criteria | Reference standard |
|---|---|---|---|---|---|
| HTRB | Tj = max, Vds=80% of Vdsmax, Vgs=0 | 1000hrs | 1×77pcs | 0/1 | JESD22-A108 |
| HTGB | Tj = max, Vgs=80% of Vgsmax, Vds=0 | 1000hrs | 1×77pcs | 0/1 | JESD22-A108 |
| HTSL/LTSL | Tj = max, Vds=80% of Vdsmax, Vgs=0 | 1000hrs | 1×77pcs | 0/1 | JESD22-A103 |
|
HAST or H3TRB |
HAST: Ta = 130°C, 85%RH, 230KPa (=33Psia) , 80% rated of Max BVdss up to to 42V(Ta= 85°C, 85% RH, 80% rated of Max BVdss up to to 100 V) |
96hrs (1000hrs) |
1×77pcs | 0/1 |
JESD22-A110 JESD22-A101 |
| TC |
Ta: -65°C to 150°C, air to air (Ta: -55°C to 150°C, air to air) |
500 cycles (1000 cycles) |
1×77pcs | 0/1 | JESD22-A104 |
|
uHAST or PCT |
Ta=130 °C, 85% RH, 230 KPa (=33 Psia) (TA=121 ℃,RH=100%, 15Psig) |
96hrs | 1×77pcs | 0/1 |
JESD22-A118 JESD22-A102 |
|
Precondition (For SMD only) |
TC: -65℃~150℃ 15min 5Cycle, HTS: 125℃ 24Hrs, TH: 30/60% 192Hrs; IR :260℃ max 3 Cycle |
N/A | 1×77pcs | 0/1 | JESD22A-113 |